Panel is located at the driver end of the driver side bench seat. The circuit breaker panel is made from .080 thick 6061-T6 aluminum sheet.  Has three single pole circuit breakers for the solar in, solar out and DC out circuit breakers.  Has one two pole circuit breaker for AC out from house inverter to the duplex outlet string.  Also has a hole in panel for the floor air vent open/close lawn mower rope.  Made panel large enough to also be used for the corner connectors for the 80/20 framework that surrounds the inset panel opening.

 

 

 

 

 

Breakers are Blue Sea "A" series AC/DC toggle circuit breakers with black switch handles.  The "solar in" DC circuit breaker located between the solar panel and the solar controller is a 15 amp Blue Sea # 7208.  The "solar out" DC circuit breaker located between the solar controller and the positive bus bar is a 20 amp Blue Sea # 7212.  The DC circuit breaker between the house battery positive bus and the 12 position Blue Sea fuse panel is a 50 amp Blue Sea # 7228.  The AC circuit breaker located between the house Magnum inverter and the first duplex outlet is a two pole 15 amp Blue Sea # 7234.

The DC wiring from solar panel to 15 amp circuit breaker and from the circuit breaker to the solar controller is # 10 AWG.  The DC wiring from solar controller and the positive bus is # 8 AWG.  The DC wiring between the positive bus bar to the 50 amp circuit breaker and between the circuit breaker and the fuse panel is # 6 AWG.  The 120 volt AC wiring from the inverter to two pole circuit breaker and between the circuit breaker and the duplex outlet are 14/3 cords.
 


Circuit Breaker Panel Drawing # ODJ127-36                                           


If you want more PDF menu choices the drawing can be saved to your computer and then reopened with Adobe PDF Reader.  The Adobe PDF Reader is a better program to use for viewing.  

bottom of page